Skip to contents

Fieldwork is expensive, and a study that is too small to detect the effect it was designed for is wasted: a non-significant result from it says almost nothing. A power analysis, done before the field season, says how many samples, plots, traps or sites are needed. tidyvisor does it for the common ecological designs and explains the answer.

Power analysis needs three things:

  1. The effect worth detecting: the smallest difference, ratio or slope that would matter biologically. It comes from the literature, from experience or from the question itself, not from the hope of a large effect.
  2. The variability: the standard deviation, or the dispersion of counts, from a pilot study or earlier work.
  3. The power and significance level: usually 80% (a 4-in-5 chance of detecting the effect if it is real) and 0.05.

Two habitats: how many trees?

Suppose a 5 cm difference in sapling height between two habitats would matter, and earlier surveys give a standard deviation of 8 cm.

tv_power("two_groups", delta = 5, sd = 8)
#> 
#> ── tidyvisor: how many samples? ────────────────────────────────────────────────
#> Question: power
#> 
#> ── What the data show ──
#> 
#> • Design: two_groups
#> • Effect to detect: difference 5.00 with SD 8.00 (Cohen's d = 0.62)
#> • Power, significance level: 80%, 0.05
#> • Needed: 42 samples per group (84 in total)
#> • If the effect is half as large: 162 samples per group
#> • If it is twice as large: 12 samples per group
#> • For 90% power: 55 samples per group
#> 
#> ── Recommended ──
#> 
#> Sample size: Collect at least 42 samples per group (84 in total)
#> Gives an 80% chance of detecting difference 5.00 with SD 8.00 (Cohen's d =
#> 0.62) at the 0.05 level; with fewer, a real effect of that size will often be
#> missed and a non-significant result will say little.
#> power.t.test(delta = 5, sd = 8, power = 0.8, sig.level = 0.05)
#> Before the field: Add a margin for losses
#> Traps fail, plots flood and samples are lost: collect 10-20% more than the
#> minimum. Randomise which units get each treatment, and record the site and date
#> of every sample.
#> Check: The effect size drives everything
#> Halving the effect roughly quadruples the sample size (see the checks). Use the
#> smallest effect that would matter biologically, from the literature or a pilot,
#> and report the power analysis with the study.

The sensitivity rows matter as much as the answer: halving the effect roughly quadruples the sample size, so being optimistic about the effect is the commonest way to end up with a study that is too small.

Counts: how many traps?

Beetle counts average 4 per pitfall trap and are overdispersed (negative binomial size 2). To detect a 1.5-fold difference between treatments:

tv_power("counts", mean1 = 4, ratio = 1.5, theta = 2)
#> 
#> ── tidyvisor: how many samples? ────────────────────────────────────────────────
#> Question: power
#> 
#> ── What the data show ──
#> 
#> • Design: counts
#> • Effect to detect: mean 4.00 against 6.00 (rate ratio 1.50), negative binomial
#>   size 2.00
#> • Power, significance level: 80%, 0.05
#> • Needed: 68 samples per group (136 in total)
#> • If the effect is half as large: 278 samples per group
#> • If it is twice as large: 17 samples per group
#> • For 90% power: 91 samples per group
#> 
#> ── Recommended ──
#> 
#> Sample size: Collect at least 68 samples per group (136 in total)
#> Gives an 80% chance of detecting mean 4.00 against 6.00 (rate ratio 1.50),
#> negative binomial size 2.00 at the 0.05 level; with fewer, a real effect of
#> that size will often be missed and a non-significant result will say little.
#> # check by simulation: power for n per group
#> sim <- function(n) {
#>   g <- gl(2, n)
#>   y <- MASS::rnegbin(2 * n, mu = 4 * c(1, 1.5)[g], theta = 2)
#>   summary(MASS::glm.nb(y ~ g))$coefficients[2, 4] < 0.05
#> }
#> mean(replicate(500, sim(68)))
#> Analysis: Negative binomial GLM
#> The calculation assumes the counts will be analysed with a count GLM;
#> overdispersion (small size) raises the sample size needed, so estimate it from
#> a pilot.
#> Before the field: Add a margin for losses
#> Traps fail, plots flood and samples are lost: collect 10-20% more than the
#> minimum. Randomise which units get each treatment, and record the site and date
#> of every sample.
#> Check: The effect size drives everything
#> Halving the effect roughly quadruples the sample size (see the checks). Use the
#> smallest effect that would matter biologically, from the literature or a pilot,
#> and report the power analysis with the study.

The calculation assumes the counts will be analysed with a negative binomial GLM, and its code checks the answer by simulation.

Plots nested in sites: how many sites?

Ecological samples usually come in clusters: quadrats in sites, traps in transects. Samples within a site are alike, measured by the intra-class correlation (ICC), so each extra sample per site adds less information than a new site.

tv_power("sites", delta = 5, sd = 8, icc = 0.2, per_site = 5)
#> 
#> ── tidyvisor: how many samples? ────────────────────────────────────────────────
#> Question: power
#> 
#> ── What the data show ──
#> 
#> • Design: sites
#> • Effect to detect: difference 5.00 with SD 8.00, intra-class correlation
#>   0.200, 5 samples per site
#> • Power, significance level: 80%, 0.05
#> • Needed: 15 sites per group (150 in total)
#> • If the effect is half as large: 59 sites per group
#> • If it is twice as large: 4 sites per group
#> • For 90% power: 20 sites per group
#> 
#> ── Recommended ──
#> 
#> Sample size: Collect at least 15 sites per group (150 in total)
#> Gives an 80% chance of detecting difference 5.00 with SD 8.00, intra-class
#> correlation 0.200, 5 samples per site at the 0.05 level; with fewer, a real
#> effect of that size will often be missed and a non-significant result will say
#> little.
#> # with pilot data, simulate the mixed model directly:
#> # m <- lme4::lmer(y ~ treatment + (1 | site), data = pilot)
#> # simr::powerCurve(simr::extend(m, along = "site", n = 40), along = "site")
#> Design: Prefer more sites to more samples per site
#> Samples within a site are correlated (ICC 0.200), so each extra sample per site
#> adds less. Sites per group needed for 1, 2, 5, 10 and 20 samples per site: 42,
#> 25, 15, 12, 10. Beyond a few samples per site, only more sites help.
#> Before the field: Add a margin for losses
#> Traps fail, plots flood and samples are lost: collect 10-20% more than the
#> minimum. Randomise which units get each treatment, and record the site and date
#> of every sample.
#> Check: The effect size drives everything
#> Halving the effect roughly quadruples the sample size (see the checks). Use the
#> smallest effect that would matter biologically, from the literature or a pilot,
#> and report the power analysis with the study.

The design row shows the trade-off: beyond a few samples per site, only more sites help. This is why the number of sites (or groups), not the number of samples, usually limits an ecological study.

Other designs

# Three or more treatments (one-way ANOVA)
tv_power("groups", means = c(10, 12, 14), sd = 5)$checks
#> # A tibble: 7 × 3
#>   check                          value                                   meaning
#>   <chr>                          <chr>                                   <chr>  
#> 1 Design                         groups                                  ""     
#> 2 Effect to detect               means 10, 12, 14 with SD 5.00 (Cohen's… ""     
#> 3 Power, significance level      80%, 0.05                               ""     
#> 4 Needed                         32 samples per group (96 in total)      ""     
#> 5 If the effect is half as large 122 samples per group                   ""     
#> 6 If it is twice as large        9 samples per group                     ""     
#> 7 For 90% power                  41 samples per group                    ""

# Occupancy or survival: proportions
tv_power("proportions", p1 = 0.2, p2 = 0.4)$checks
#> # A tibble: 7 × 3
#>   check                          value                               meaning
#>   <chr>                          <chr>                               <chr>  
#> 1 Design                         proportions                         ""     
#> 2 Effect to detect               0.200 against 0.400                 ""     
#> 3 Power, significance level      80%, 0.05                           ""     
#> 4 Needed                         82 samples per group (164 in total) ""     
#> 5 If the effect is half as large 294 samples per group               ""     
#> 6 If it is twice as large        23 samples per group                ""     
#> 7 For 90% power                  109 samples per group               ""

# A regression slope explaining 10% of the variation, with 3 predictors
tv_power("regression", r2 = 0.1, predictors = 3)$checks
#> # A tibble: 7 × 3
#>   check                          value                                   meaning
#>   <chr>                          <chr>                                   <chr>  
#> 1 Design                         regression                              ""     
#> 2 Effect to detect               partial R squared 0.100 with 3 predict… ""     
#> 3 Power, significance level      80%, 0.05                               ""     
#> 4 Needed                         73 observations (73 in total)           ""     
#> 5 If the effect is half as large 152 observations                        ""     
#> 6 If it is twice as large        34 observations                         ""     
#> 7 For 90% power                  97 observations                         ""

# A correlation of 0.3
tv_power("correlation", r = 0.3)$checks
#> # A tibble: 7 × 3
#>   check                          value                         meaning
#>   <chr>                          <chr>                         <chr>  
#> 1 Design                         correlation                   ""     
#> 2 Effect to detect               r = 0.300                     ""     
#> 3 Power, significance level      80%, 0.05                     ""     
#> 4 Needed                         85 observations (85 in total) ""     
#> 5 If the effect is half as large 347 observations              ""     
#> 6 If it is twice as large        20 observations               ""     
#> 7 For 90% power                  113 observations              ""

# Before-after on the same plots
tv_power("paired", delta = 2, sd = 4)$checks
#> # A tibble: 7 × 3
#>   check                          value                                   meaning
#>   <chr>                          <chr>                                   <chr>  
#> 1 Design                         paired                                  ""     
#> 2 Effect to detect               mean difference 2.00 with SD of differ… ""     
#> 3 Power, significance level      80%, 0.05                               ""     
#> 4 Needed                         34 pairs (34 in total)                  ""     
#> 5 If the effect is half as large 128 pairs                               ""     
#> 6 If it is twice as large        10 pairs                                ""     
#> 7 For 90% power                  44 pairs                                ""

From pilot data

With a pilot study, tidyvisor estimates the variability from it; only the effect has to be given. Here the PlantGrowth data stand in for a pilot, and a difference of 0.5 g in dry weight is the effect of interest:

advise(PlantGrowth, question = "power", response = "weight",
       group = "group", delta = 0.5)
#> Registered S3 method overwritten by 'parsnip':
#>   method          from 
#>   print.nullmodel vegan
#> 
#> ── tidyvisor: how many samples? ────────────────────────────────────────────────
#> Question: power
#> 
#> ── What the data show ──
#> 
#> • From the pilot: 30 observations of weight — within-group SD 0.623
#> • Design: two_groups
#> • Effect to detect: difference 0.500 with SD 0.623 (Cohen's d = 0.80)
#> • Power, significance level: 80%, 0.05
#> • Needed: 26 samples per group (52 in total)
#> • If the effect is half as large: 99 samples per group
#> • If it is twice as large: 8 samples per group
#> • For 90% power: 34 samples per group
#> 
#> ── Recommended ──
#> 
#> Sample size: Collect at least 26 samples per group (52 in total)
#> Gives an 80% chance of detecting difference 0.500 with SD 0.623 (Cohen's d =
#> 0.80) at the 0.05 level; with fewer, a real effect of that size will often be
#> missed and a non-significant result will say little.
#> power.t.test(delta = 0.5, sd = 0.623374627271536, power = 0.8, sig.level = 0.05)
#> Before the field: Add a margin for losses
#> Traps fail, plots flood and samples are lost: collect 10-20% more than the
#> minimum. Randomise which units get each treatment, and record the site and date
#> of every sample.
#> Check: The effect size drives everything
#> Halving the effect roughly quadruples the sample size (see the checks). Use the
#> smallest effect that would matter biologically, from the literature or a pilot,
#> and report the power analysis with the study.

For pilot counts, give the rate ratio; the mean and the dispersion come from the pilot:

advise(InsectSprays, question = "power", response = "count", ratio = 1.5)$checks
#> # A tibble: 8 × 3
#>   check                          value                                   meaning
#>   <chr>                          <chr>                                   <chr>  
#> 1 From the pilot                 72 observations of count                "mean …
#> 2 Design                         counts                                  ""     
#> 3 Effect to detect               mean 9.50 against 14.2 (rate ratio 1.5… ""     
#> 4 Power, significance level      80%, 0.05                               ""     
#> 5 Needed                         54 samples per group (108 in total)     ""     
#> 6 If the effect is half as large 216 samples per group                   ""     
#> 7 If it is twice as large        14 samples per group                    ""     
#> 8 For 90% power                  72 samples per group                    ""

and with sites, give site and the ICC is estimated as well.

Do not use the pilot’s own difference as the effect: pilot effects are noisy, and a study powered on an overestimate is too small. Use the smallest effect that would matter.

For mixed models and complex designs

The formulas above cover the common designs. For a generalised linear mixed model, simulate: fit the model to pilot data, extend it to more sites and estimate the power by refitting to simulated data, with the simr package (Green and MacLeod 2016; Johnson et al. 2015). The code is in the advice for design = "sites".

References

Cohen, J. (1988). Statistical Power Analysis for the Behavioral Sciences, second edition. Lawrence Erlbaum.

Green, P. and MacLeod, C. J. (2016). SIMR: an R package for power analysis of generalized linear mixed models by simulation. Methods in Ecology and Evolution 7, 493-498.

Johnson, P. C. D., Barry, S. J. E., Ferguson, H. M. and Mueller, P. (2015). Power analysis for generalized linear mixed models in ecology and evolution. Methods in Ecology and Evolution 6, 133-142.

Zhu, H. and Lakkis, H. (2014). Sample size calculation for comparing two negative binomial rates. Statistics in Medicine 33, 376-387.